Meny
Meny
Din kundvagn
Vår webbplats använder cookies. Genom att fortsätta godkänner du användningen av cookies. För att neka cookies, ändra inställningarna i din webbläsare och radera lagrade cookies.

faq

Here you will find answers to the most common questions about our products — how to choose between a scaffold tower and a folding tower, what working height means and how our products meet safety standards.

Scaffold tower or folding tower: how to choose?

Our catalogue has two main product types: the scaffold tower and the folding tower. Below we explain how they differ and which to choose for a given job.

What is the main difference between a scaffold tower and a folding tower?

The main difference is the base of the structure (the frame), and therefore the way it is assembled:

  • The scaffold tower is assembled from separate 2 m frames (7 rungs) joined by diagonal and horizontal braces. It is also called a universal tower, because the same structure can take platforms of different lengths (190, 250 or 305 cm) and different working heights — up to 14.2 m. That is why it suits a wider range of jobs, though it is heavier and takes longer to assemble.
  • The folding tower rests on one folding frame with 6 rungs that folds in half. It is precisely because of this folding base frame that it is called folding. One person can unfold and set it up in a few minutes without tools; the structure is more compact, lighter and cheaper.
ParameterScaffold tower (universal)Folding tower
Base / frame2 m frames, 7 rungsfolding frame, 6 rungs (folds in half)
Assemblyfrom separate framesfast, one person, in minutes
Platform190, 250 or 305 cm190 cm
Wheels (standard)200 mm, adjustable (+spindle)125 mm (replaceable with 200 mm adjustable)
Working height4.2–14.2 m3–7.8 m
Width75 / 90 / 135 cm75 / 90 / 135 cm
Main usehigher and outdoor workindoor work, quick moving

Which one should I choose for my work?

  • The folding tower is ideal for indoor work and situations where quick assembly, compact storage and easy moving matter: painting, plastering, repairing ceilings and walls.
  • The scaffold tower is intended for higher and outdoor work — façades, construction, installation — where you need a greater working height (up to 14.2 m) or a longer platform (250 or 305 cm).

In the shared range (up to ~8 m) both types give the same working height; only the assembly speed, platform length and wheels differ.

Which width should I choose: 75, 90 or 135 cm?

  • Up to about 5 m working height, 90 cm is the optimal width: it is stable without extra stabilisers and lets you work in the middle of a room, not only against a wall. A 75 cm structure placed in the middle of a room usually needs stabilisers on both sides.
  • From 6 m working height, both types are supplied with two stabilisers as standard, regardless of width. The 135 cm platform is very stable and many customers use it without stabilisers.

How wide is the platform?

The platform width is not the same as the structure width. This is a common misunderstanding: when choosing a 90 cm width, many people expect a 90 cm platform.

  • 75 cm — one 60 cm platform.
  • 90 cm — a standard 60 cm platform (centred, with about 15 cm left on each side). You can add a 30 cm platform: at the same level as the main one it gives a full-width 90 cm working surface; lower down it serves as a step, higher up as a tool shelf.
  • 135 cm — two 60 cm platforms (120 cm working surface).

Tip: if you need the extra 30 cm platform, it is most economical to add it when ordering — that way it is about 30% cheaper than buying it separately later from the Parts section.

Does the folding tower reach the same height as the scaffold tower?

Yes, in the shared range (up to ~8 m). On folding towers with 3.8 / 5.8 / 7.8 m working height, the upper guard frames can be replaced with 1 m frames with 4 rungs, which raise the platform by about 28 cm. If you also swap the 125 mm wheels for 200 mm adjustable ones (another ~10 cm), the folding tower's working height becomes practically the same as the scaffold tower's (for example, 3.8 m → ~4.2 m). For higher work (above 8 m) you still need the scaffold tower, which reaches up to 14.2 m.

Which one is cheaper?

The folding tower is usually €80–100 cheaper than the scaffold tower with equivalent equipment (same number of platforms, stabilisers, 200 mm adjustable wheels). This is because its folding frame requires fewer connecting parts.

Heights and dimensions

How is working height calculated?

Working height is not the same as platform height:

  • Platform height: the distance from the ground to the surface the operator stands on.
  • Working height = platform height + about 2 m (the average reach of a person with arms raised).

For example, if the platform is at 6 m, the working height is about 8 m.

What platform widths and lengths are available?

  • Width: 75, 90 and 135 cm.
  • Platform length: scaffold tower — 190, 250 or 305 cm; folding tower — 190 cm.

Can the structure be used on an uneven surface?

Yes. The scaffold tower comes as standard with 200 mm adjustable wheels with a spindle, which let you level the structure on uneven or sloping surfaces and add about 40 cm of working height. The folding tower comes with 125 mm wheels as standard, which can be swapped for 200 mm adjustable ones when needed.

Safety and quality

Are they certified?

Yes. All our products comply with the European standard EN 1004 and are certified by TÜV Nord. They are made in Holland (Euroscaffold / Alumexx).

What warranty do they have?

We offer a 5-year manufacturer's warranty. On the welds — a lifetime warranty.

Who can assemble it and how long does it take?

Anyone can assemble it by following the manufacturer's instructions. One person assembles a folding tower in a few minutes; a scaffold tower takes longer, as it is built from separate frames.

Why choose an aluminium structure?

Aluminium is light, rustproof and durable. That is why aluminium towers and scaffolds are easier to move than steel scaffolds, need no special maintenance and last a long time.